ReVibe Anura™
Installation and operating instructions
Self-powered monitoring system for vibrating screens
Copyright© ReVibe Energy AB 2022
Safety instructions
When this product has reached the end of its life it must be
treated as Waste Electrical & Electronic Equipment (WEEE).
Any WEEE marked products must not be mixed with general
household waste, but kept separate for the treatment, recovery
and recycling of the materials used. Contact your local authori-
ty for details of recycling schemes in your area.
Safety guidelines
Copyright© ReVibe Energy AB 2022. All rights reserved.
This equipment generates, uses and can radiate radio frequency energy
and, if not installed and used in accordance with the instruction manual,
may cause harmful interference to radio communications. Operation of
this equipment in a residential area is likely to cause harmful interference
in which case the user will be required to correct the interference at his
own expense.
2
Conformity
The regulatory intent is that any consumer of a device can pick up a prod-
uct manual and know exactly who has manufactured the product.
The system is CE certified.
Table of contents
Anura™ system
Introduction.....................................4
System parts...................................5
Gateway specifications
Gateway...........................................6
Interface LED.................................. 7
Interface connectors..................... 8
Technical data................................9
Dimensions...................................10
Sensor node specifications
Sensor node..................................11
Technical data..............................12
Dimensions...................................13
Transceiver specifications
Transceiver...................................14
Technical data.............................15
Dimensions..................................16
Copyright© ReVibe Energy AB 2022. All rights reserved.
3
Installing Anura™
Nodes.............................................17
Gateway..........................................18
Tranceivers.....................................18
Operation Anura™
First start.......................................19
Anura™ support
Report faults..................................20
Contact information.....................20
Copyright© ReVibe Energy AB 2022. All rights reserved.
A self-powered fit-and-forget industrial monitoring systems designed to
monitor the status of a vibrating screen through eight (8) wireless sensor
nodes. The system transmits data wirelessly to cloud services where it
can be accessed by the user to understand the status of the screen and
act before a potential breakdown and plan maintenance well ahead of
time.
4
Together with analysis options to optimize performance
and flow rate, ReVibe Anura will be every operator's system
of choice.
Anura™ introduction
Copyright© ReVibe Energy AB 2022. All rights reserved.
21
3
4
5
6 7 8 9 10
11 12
13
14
15 16
21
3
4
5
6 7 8 9 10
11 12
13
14
15 16
B
A
C
D
E
F
G
H
I
J
K
L
B
A
C
D
E
F
G
H
I
J
K
L
87
225
254
87
156
21
3
4
5
6 7 8 9 10
11 12
21
3
4
5
6 7 8 9 10
11 12
B
A
C
D
E
F
G
H
B
A
C
D
E
F
G
H
161
87
80
80
1
A
2
3
4
5
6 7 8
1 2
3
4
5
6 7 8
B
C
D
E
F
A
B
C
D
E
F
120
66
94
Anura™ system parts
5
1
1
2
2
3
3
4
4
5
5
6
6
AA
BB
CC
DD
20335_ANTI-SLIP MOUNTING GUIDE.stp
20335_ANTI-SLIP MOUNTING GUIDE
PCE-RVE 2022-11-04
A
Designed by Approved by
Date
1 / 1
Rev
Sheet
Material
Mass
Generic
N/A
Project
Name
REV DESCRIPTION DATE
A
New Article
2022-11-04
Anura
TGA
1) MATERIAL: RUBBER - EPDM 70 SHORE A, BLACK
2) APPLIED ON ONE FACE, VERY HIGH BOND ADHESIVE WITH PROTECTIVE FOIL
3) NON STATED DIMENSIONS REFER TO 3D-STEP-FILE: 20335_ANTI-SLIP MOUNTING GUIDE.stp
4) CONTOUR ACCURACY
`0,2
See note 1)
2
`0,2
ADHESIVE SIDE
SEE NOTE 2)
126
43,45
52,25
2323
101,3
n333x
Gateway
5 m power cable
Transceiver
5 m cable
Sensor node
Anti-slip
mounting guide
A-A ( 1 : 2 )
1
1
2
2
3
3
4
4
5
5
6
6
AA
BB
CC
DD
20330 ANGLED BRACKET 90 DGR SENSOR NODE.stp
20330 ANGLED BRACKET 90 DGR SENSOR NODE20330 ANG
L
PCE-RVE 2022-10-28
A
Designed by Approved by
Date
1 / 1
Rev
Sheet
Material
Mass
Generic
N/A
Project
Name
A
A
REV DESCRIPTION DATE
A
New Article, Reviewed by NIL
2022-10-28
5
`
0,15
R5 MAX
ROLLING DIRECTION
134
69
R65()
R2,922x
n25,8
R202x
128
24
46,5
69
90
21()
64
86
R212x
TGA
Anura
1) NON STATED DIMENSIONS, REFER TO 3D-STEP-FILE: 20330 ANGLED BRACKET 90 DGR SENSOR NODE.stp
A
B
C
n8,54x H12
n51,5
2) GENERAL TOLERANCE IF NOTHING ELSE STATED:
d 0,3 A BC
5,811x ( )
j
0,2 A B C
3) MATERIAL: SHEET METAL STEEL 355, t=5mm
4) TO BE TUMBLED, NO SHARP EDGES
5) SURFACE TREATMENT: POWDER COATING RAL 9005 BLACK, OUTDOOR ENVIRONMENT - SEALED PROTECTION, NO CORROSION
j
0,2 AB C
6) DIMENSIONS ARE TO BE MEASSURED BEFORE POWDER COATING
90°±0,
5
°
SEE NOTE 3)
Angled-bracket
for central mounting
Ethernet cable
10 m
2
1
3
4
5
6 7 8 9 10
11 12
13
14
15 16
21
3
4
5
6 7 8 9 10
11 12
13
14
15 16
B
A
C
D
E
F
G
H
I
J
K
L
B
A
C
D
E
F
G
H
I
J
K
L
87
225
254
87
156
21
3
4
5
6 7 8 9 10
11 12
13
14
15 16
21
3
4
5
6 7 8 9 10
11 12
13
14
15 16
B
A
C
D
E
F
G
H
I
J
K
L
B
A
C
D
E
F
G
H
I
J
K
L
87
225
254
87
156
Spirit level
mounting guide
21
3
4
5
6 7 8 9 10
11 12
13
14
15 16
21
3
4
5
6 7 8 9 10
11 12
13
14
15 16
B
A
C
D
E
F
G
H
I
J
K
L
B
A
C
D
E
F
G
H
I
J
K
L
87
225
254
87
156
Anura™ gateway
The Anura™ gateway connects the individual system parts and gathers
the data, making it available to users by seamless upload to the cloud.
Built with rugged black anodized aluminium to withstand harsh environ-
ments and utilizing industrial grade connectors to provide secure connec-
tions. Anura™ gateway ensures operation of the whole system.
Copyright© ReVibe Energy AB 2022. All rights reserved.
6
3
1
2
Copyright© ReVibe Energy AB 2022. All rights reserved.
Gateway interface
The gateway interface indicator LED:s
1. Power LED (Purple when powered on and running)
2. Transceiver LEDs (Blue when transceiver is connected)
One for each transceiver
3. Sensor status LEDs (Blue when sensor is connected)
4. LAN/WAN LED (Green when connected to Internet)
5. Ethernet LED (Flashes blue when communicating)
7
21
3
4
5
6 7 8 9 10
11 12
13
14
15 16
21
3
4
5
6 7 8 9 10
11 12
13
14
15 16
B
A
C
D
E
F
G
H
I
J
K
L
B
A
C
D
E
F
G
H
I
J
K
L
87
225
254
87
156
54
0000000-0000-0000-0000-0000000000000000000-0000-0000-0000-000000000000
Made in SwedenMade in Sweden
IP65IP65
8
6
7
9
Copyright© ReVibe Energy AB 2022. All rights reserved.
1
4
Check "Sensor status" LED
for connectivity info
Transc
.
Eth.
Sensor status
Sensor power 5V
A
A
B
B
INSIDE
Power
Gateway interface
The gateway interface connectors
6. 6x M8 connectors power supply cabled sensor nodes
7. 2x M12 Transceiver connectors
8. 1x RJ45 connector or M12 D-coded connector
9. Power cable
10. QR-code identifying the system. Scan for info
8
21
3
4
5
6 7 8 9 10
11 12
13
14
15 16
21
3
4
5
6 7 8 9 10
11 12
13
14
15 16
B
A
C
D
E
F
G
H
I
J
K
L
B
A
C
D
E
F
G
H
I
J
K
L
87
225
254
87
156
10
0000000-0000-0000-0000-0000000000000000000-0000-0000-0000-000000000000
Made in SwedenMade in Sweden
IP65IP65
Technical data Gateway
Weight 2940 g
Measurement 230 mm x 150 mm x 70 mm
Operating temperature -40°C to +80° C (-40°F to 176°F)
Power supply 110V - 230V AC to 12V DC
Power cable length 5 m
Ingress protection IP65
Casing material Black anodized aluminium
Communication connector 1x M12 D-coded to Ethernet RJ45
Ethernet cable length 10 m
Cabled node connectors 6x M8 5V DC
Transceiver connectors 2x M12 5V DC
Copyright© ReVibe Energy AB 2022. All rights reserved.
9
Copyright© ReVibe Energy AB 2022. All rights reserved.
21
3
4
5
6 7 8 9 10
11 12
13
14
15 16
21
3
4
5
6 7 8 9 10
11 12
13
14
15 16
B
A
C
D
E
F
G
H
I
J
K
L
B
A
C
D
E
F
G
H
I
J
K
L
87
225
254
87
156
Gateway dimensions
10
156
87
87
254
225
Gateway should be mounted in the direction provided
above to protect connectors.
Anura™ sensor node
1
A
2
3
4
5
6 7 8
1 2
3
4
5
6 7 8
B
C
D
E
F
A
B
C
D
E
F
120
66
94
The harvester sensor node takes advantage of the screen's own vibrations
in order to power the sensor and radio communication, completely elim-
inating the need for batteries or power cables. The high grade acceler-
ometer delivers accurate vibration data transmitted over the 2.4 GHz BLE
standard. Mounts with 3 industrial neodymium magnets.
Horizontal mount using anti-slip guide.
Copyright© ReVibe Energy AB 2022. All rights reserved.
11
Copyright© ReVibe Energy AB 2022. All rights reserved.
Technical data sensor node
Weight 820 g
Measurement 120 mm x 94 mm x 66 mm
Operating temperature -40°C to +80°C (-40°F to 176°F)
Power supply Self-powered through vibration energy harvester.
Ingress protection IP68
Casing material PA12 casing with aluminium base plate
Mounting 3 neodymium magnets
Communication protocol Bluetooth Low Energy
Wireless range 50 m line of sight
Time accuracy (between nodes) <5 ms
Acceleration measurements Amplitude range: +- 16G
Measurement axis: X, Y, Z
Sample rate: Congurable, up to 13kHz
Accelerometer bandwidth: DC to 5.5kHz
12
Sensor node dimensions
1
A
2
3
4
5
6 7 8
1 2
3
4
5
6 7 8
B
C
D
E
F
A
B
C
D
E
F
120
66
94
Copyright© ReVibe Energy AB 2022. All rights reserved.
13
94
120
66
Anura™ transceiver
21
3
4
5
6 7 8 9 10
11 12
21
3
4
5
6 7 8 9 10
11 12
B
A
C
D
E
F
G
H
B
A
C
D
E
F
G
H
161
87
80
80
The bridge connecting the nodes to the gateway.
Copyright© ReVibe Energy AB 2022. All rights reserved.
14
Copyright© ReVibe Energy AB 2022. All rights reserved.
Transceiver specications
Weight 400 g
Measurement 161 mm x 80 mm x 80 mm
Operating temperature -40°C to +80°C (-40°F to 176°F)
Power supply 5V DC
Ingress protection IP68
Casing material PA12
Wireless communication protocol Bluetooth Low Energy
Connector 1x M12
Cable length 5 m
15
Transceiver dimensions
21
3
4
5
6 7 8 9 10
11 12
21
3
4
5
6 7 8 9 10
11 12
B
A
C
D
E
F
G
H
B
A
C
D
E
F
G
H
161
87
80
80
Copyright© ReVibe Energy AB 2022. All rights reserved.
16
161
87
80
80
Installing Anura™
Copyright© ReVibe Energy AB 2022. All rights reserved.
Install the sensor nodes in the preferred location on the vibration screen.
Use the anti-slip mounting guide combined with a spirit level to achieve
a leveled operation of the sensor node, this ensures correctly calibrated
data during operation.
17
1
A
2
3
4
5
6 7 8
1 2
3
4
5
6 7 8
B
C
D
E
F
A
B
C
D
E
F
120
66
94
y
x
y
x
y
x
1
A
2
3
4
5
6 7 8
1 2
3
4
5
6 7 8
B
C
D
E
F
A
B
C
D
E
F
120
66
94
1
2
Copyright© ReVibe Energy AB 2022. All rights reserved.
18
Installing Anura™
1
A
2
3
4
5
6 7 8
1 2
3
4
5
6 7 8
B
C
D
E
F
A
B
C
D
E
F
120
66
94
y
x
y
x
21
3
4
5
6 7 8 9 10
11 12
21
3
4
5
6 7 8 9 10
11 12
B
A
C
D
E
F
G
H
B
A
C
D
E
F
G
H
161
87
80
80
y
x
21
3
4
5
6 7 8 9 10
11 12
13
14
15 16
21
3
4
5
6 7 8 9 10
11 12
13
14
15 16
B
A
C
D
E
F
G
H
I
J
K
L
B
A
C
D
E
F
G
H
I
J
K
L
87
225
254
87
156
Gateway
Transceiver
Node
Vibrating screen
Installing Anura™
Place the transceivers within line-of sight to the sensor nodes. Placement
should be elevated on both sides of the screen.
The gateway mounts in a vertical position to protect against water ingres-
sion.
Connect ethernet cable to router providing internet access.
Anura™ system comes pre-configured and will be operational after setting
it up according to installation recommendations. A correctly working
Anura™ system automatically starts to send measurement data when the
vibrating screen is operational.
Note: The harvester node contains a supercapacitor. If the supercapacitor
is completely depleted, a startup time of up to ~7 minutes is required in
order for the node to be sufficiently charged and able to send data.
A charged supercapacitor enables the node to be in standby mode for up
to 16 hours. Subsequent operation will be quick and responsive within this
timeframe.
If the node loses connection to the gateway and thus the ability to upload
data to the cloud. The node buffers 4 hours of data in memory and sends
the stored data buffer when connection to the gateway is restored.
Copyright© ReVibe Energy AB 2022. All rights reserved.
19
Support
Reporting a fault with your Anura™ system.
To ensure that we will be able to provide the best support for your Anura™
system, we kindly ask you to describe the problem as detailed as possible.
Please find the QR code (see page 8 in this manual) and attach a picture
of this, along with the fault report. This helps us in identifying your sys-
tem.
Send fault report to anurasupport@revibeenergy.com
20
Revibe Energy AB
Falkenbergsgatan 3
412 85 Göteborg
Sweden
+46 (0) 31 24 23 22
www.revibeenergy.com
Contact information
Important information
Copyright© ReVibe Energy AB 2022. All rights reserved.
Manual version: 001
For the latest version of the Installation and operating instructions,
please visit www.revibeenergy.com/anura
Copyright© ReVibe Energy AB 2022